 DC-DC
120 Watts MQP Series
* * * * * * * 9.5 VDC to 40 VDC Input MIL-STD-461E Compliance Isolated Output Regulated Output
xppower.com
Continuous Short Circuit Protection Five-Sided Metal Case Rugged Construction
Specification
Input
Input Voltage Range Input Current Input Transient * 9.5-40 VDC * See models & ratings table * MIL-STD-1275A-D, MIL-STD-704A when used in conjuction with DSF200/DSF500 filter module (see application notes) * 9.0-9.1 VDC
General
Efficiency Isolation Voltage * See model & ratings table * 3000 VAC Input to Output 1500 VAC Input to Case 1500 VAC Output to Case * Typically 300 kHz * Up to 26.7 W/In3 * Baseplate cooled * 1 MHrs +25 C
Undervoltage Lockout Protection
Output
Output Voltage Output Voltage Adjustment Minimum Load Line Regulation Load Regulation Turn-on Time Ripple & Noise Overvoltage Protection Overcurrent Protection Short Circuit Protection Overtemperature Protection Current Share * See models & ratings table * 70-110% * * * * * * * * * No minimum load required 0.6% 0.6%, 10-100% load Typically 100 ms 3%, 20 MHz BW 120% typical 108-115% (see application notes) Continuous +101C to +107 C case temperature
Switching Frequency Power Density Package Style MTBF
Environmental
Operating Temperature * -40 C to +85 C Storage Temperature * -50 C to +125 C Case Temperature * +100 C max, thermal resistance case to ambient (CA) 5.5 C/W Shock Vibration * EN61373 Category 1, Class B * EN61373 Category 1, Class B
EMC & Safety
Conducted Emissions Conducted Susceptibility Immunity * MIL-STD-461E with external components (see application notes) * MIL-STD-461E CS101, CS114, CS115, CS116 with DSF200LV filter (see application notes) * MIL-STD-1275A-D with DSF200LV filter (see application notes)
* Max 4 modules, derate total output current to 90% (see application notes)
DC-DC
Models and Ratings
Output Voltage 3.3 5.0 12.0 15.0 24.0 VDC VDC VDC VDC VDC Output Current 18.2 16.0 7.9 7.0 4.8 A A A A A Typical Input Current(2) 2.8 3.6 4.3 4.7 5.1 A A A A A Efficiency 76% 78% 79% 79% 80% 60 80 95 105 115
MQP Series
Max Output Power W W W W W Model Number(1) MQP12028S3V3 MQP12028S05 MQP12028S12 MQP12028S15 MQP12028S24
Notes
1. For integrated heatsink models add suffix `-H' to model number. 2. 28 V input at full load.
Mechanical Details
MQP120
0.40 (10.1) 0.45 (11.5)
3.74 (95.0)
2.56 (65.0)
3.46 (88.0) 3.41 (86.7)
o0.47 (12.0) 2.28 (58.0)
Top View 1.32 (33.5)
PCB Track Clearance Area
1
0.14 (3.5)
1
34
6789
16 17
24 25
29 30
0.25 (6.3)
o0.04 (1.0)
0.27 (6.9)
o0.14 (3.6)
0.14 (3.5) 0.26 (6.5) 2.90 (73.7)
MQP120-H
3.74 (95.0) 2.56 (65.0)
1.39 (35.4)
PIN CONNECTIONS Pin Function 1 Case 3 +Vin 4 +Vin 6 -Vin 7 -Vin 8 En 9 St 16 Ot 17 Tr 24 -Vout 25 -Vout 29 +Vout 30 +Vout
0.25 (6.3)
o0.04 (1.0)
3.46 (88.0) 3.41 (86.7)
o0.47 (12.0) 2.28 (58.0)
Top View
PCB Track Clearance Area
1
0.14 (3.5)
1
34
6789
16 17
25
29
o0.14 (3.6)
0.14 (3.5) 0.26 (6.5) 2.90 (73.7)
1.32 (33.5)
0.27 (6.9)
DC-DC
Derating Curves
MQP120 vs ambient temperature (module only)
120
MQP Series
100
80 Output Power (Watts) 3v3 5 12 15 24
60
40
20
0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 Ambient Temperature (C)
MQP120-H vs ambient temperature (integrated heatsink)
120
100
80 Output Power (Watts) 3v3 5 12 15 24
60
40
20
0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 Ambient Temperature (C)
Heatsink requirements for maximum output power C/W
6
5
Heatsink Performance (C/W)
4 3v3 5 12 15 24
3
2
1
0 85 80 70 60 50 40 30 20 10 0 Ambient Temperature (C)
DC-DC
Typical Efficiency (MQP12028S24)
Efficiency vs Load
90%
MQP Series
85%
80% Efficiency % 9V Input 12V Input 28V Input 40V Input
75%
70%
65%
60% 0%
20%
40% Load %
60%
80%
100%
Typical Overcurrent Protection
120.0
100.0
80.0 Vout / %
60.0
40.0
20.0
0.0
0 10 20 30 40 50 60 70 80 90 100 110 120
Iout / %
Application Notes
Output Adjustment (Tr)
+V TRIM DOWN Tr TRIM UP -V
Model MQP12028S3V3 MQP12028S05 MQP12028S12 MQP12028S15 MQP12028S24
OUTPUT ADJUSTMENT RANGE Minimum Maximum Trim Down 3.3 V 3.6 V 0.0 4.3 V 5.5 V 85.0 8.4 V 13.2 V 2.0 10.5 V 16.5 V 1.3 k 16.8 V 26.4 V 5.4 k
Trim Up 1.0 k 2.4 k 1.0 k 1.3 k 1.6 k
DC-DC
Application Notes
Enable (En)
MQP Series
+
Input
-
MQP120
En
En floating = Output on En connected -Vin = Output off
Input current typically 10 mA with output inhibited.
Parallel Operation Start-up (St) If the MQP120 modules are to be used in parallel a droop share methodology must be used to ensure that each converter shares the load equally. The `St' pins should be connected together to ensure reliable start-up.
RDroop
+
+
Input
-
MQP120
St -
Load
RDroop
+
St
+
MQP120
-
Overtemperature Warning (Ot) Open collector transistor gives +5 C warning of thermal shutdown. Transistor is referenced to -Vout.
Module
Max 25 V 30 mA
Ot Collector Pin 16
Transistor On : Temp warning Transistor Off : Temp OK
-Vout
Application Notes
Conducted EMI MQP12028S24, Limit MIL-STD-461E
2.2 mH
MQP Series
+
470 f
+
Vin
4.7 nf
MQP12028S24
Case 4.7 nf 4.7 nf
RLoad
M
R
Conducted EMI MQP12028S24, Limit MIL-STD-461E
+
470 f
+
Vin
DSF200LV
4.7 nf
MQP12028S24
Case 4.7 nf 4.7 nf
RLoad
28-Feb-08


▲Up To Search▲   

 
Price & Availability of MQP12028S05

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X